Refusol Inverters
Purpose
The purpose of this plugin is to collect data from Refusol Inverters.
Usage
This plugin reads the data from Refusol Inverters, via serial or TCP. Inverter data will be collected to the solar
table. By default, it will collect data every 5 minutes, but can collect at a minimum rate of 30 seconds
due to the slow response of the Refusol protocol. The plugin will make 4
attempts (by default) to read an inverter. The following data will be collected:
Connection over a TCP Proxy
Some sites that have Refusol inverters connected via a serial line allow access over a TCP Gateway such as a MOXA Nport 5232. In these cases, please ensure that the Packing Length
for the TCP server has been set to 24
. Also ensure that the correct serial port parameters have been set.
Arguments
Arguments are as follows:
endpoint
. This is either a serial device like/dev/ttyS0
or an IP or DNS like192.168.1.15
bus_addresses
. An RS485 address in the range 2-63. This can be a hyphenated list like3-10
or a list like2,5,7,9
--port
. This is an optional parameter used in an Ethernet gateway, and is the TCP port used for the gateway. Default is4001
--attempts
. This is an optional parameter, and determines how many times to times to attempt to read an inverter value. Default is4
--delay
. This is the delay in seconds between inverter send and receive commands, AND ifattempts
> 1. Fractions like0.3
can be used. Default is0.1
--timeout
. This is the read timeout in seconds; or the amount of time to wait for data to arrive. Fractions like0.3
can be used. Default is0.1
--baud
. This is the baud rate when using a serial device. The default is57600