Ingecon 100TL Inverters

Purpose

The purpose of this plugin is to collect data from Ingecon 100TL Inverters via Modbus.

Usage

This plugin reads the data from Ingecon 100TL Inverters via Modbus. This plugin relies on the Modbus Ardexa plugin. It uses the Modbus TCP Specification, and collects from RS485 or TCP connected inverters. Inverter data will be collected to the solar table. The plugin will be run every 5 minutes, by default. The following data is collected from the inverters. Strings data (DC Current values below) will only appear if the String kit on is connected

Variable                     Units
==================================
Total Energy                Wh
Operating Hours             h
Number of Connections
Daily Energy                Wh
Stop Event Code
Warning Code
Status
AC Current 1                A
AC Current 2                A
AC Current 3                A
AC Voltage 1                V
AC Voltage 2                V
AC Voltage 3                V
Grid Freq                   Hz
Apparent Power              VA
Active Power                W
Reactive Power              var
Cos Phi
DC Current 1                A
DC Voltage 1                V
DC Power 1                  W
Isol Resist                 MOhm

DC Current 1                A
DC Current 2                A
DC Current 3                A
DC Current 4                A
DC Current 5                A
DC Current 6                A
DC Current 7                A
DC Current 8                A
DC Current 9                A
DC Current 10               A
DC Current 11               A
DC Current 12               A
DC Current 13               A
DC Current 14               A
DC Current 15               A
DC Current 16               A
DC Current 17               A
DC Current 18               A
DC Current 19               A
DC Current 20               A
DC Current 21               A
DC Current 22               A
DC Current 23               A
DC Current 24               A

Arguments

Arguments are as follows:

  • endpoint. This is either a serial device like /dev/ttyS0 or an IP or DNS like 192.168.1.15

  • bus_addresses. An RS485 address in the range 2-63. This can be a hyphenated list like 3-10 or a list like 2,5,7,9

  • --port. This is an optional parameter used in an Ethernet gateway, and is the TCP port used for the gateway. Default is 502

  • --attempts. This is an optional parameter, and determines how many times to times to attempt to read an inverter value. Default is 1

  • --delay. This is the delay in seconds between inverter send and receive commands, AND if attempts > 1. Fractions like 0.3 can be used. Default is 0.05