Plus ES Meters

Purpose

The purpose of this plugin is to collect data from Plus ES Meters.

Usage

This plugin reads the data from Plus ES Meters via serial or TCP ( See: https://pluses.com.au/). Meter data will be collected to the meter table. By default, it will collect data every 5 minutes, but can collect at a minimum rate of about 0.3 seconds via TCP. The plugin will make 1 attempt (by default) to read the meter. This plugin relies on the Modbus Ardexa plugin. Please note that at the moment, it collects from the following fixed multipliers. If any of them are different, please contact Ardexa. The default RTU (Modbus) address should be 33.

K (Meter Mutliplier) = 120,000
VT  (Voltage Mutliplier) = 600
CT  (Current Mutliplier) = 200

The following data is collected:

Variable                    Units
==================================
Grid Freq                   Hz
Power Factor
AC Voltage L1-L2            V
AC Voltage L3-L1            V
AC Voltage L2-L3            V
AC Current 1                A
AC Current 2                A
AC Current 3                A
Phase 1 Angle               °
Phase 2 Angle               °
Phase 3 Angle               °
Phase 1 Power               kW
Phase 2 Power               kW
Phase 3 Power               kW
Exported Energy             kWh
Exported Reactive           kvarh
Imported Energy             kWh
Imported Reactive           kvarh

Arguments

Arguments are as follows:

  • endpoint. This is either a serial device like /dev/ttyS0 or an IP or DNS like 192.168.1.15

  • bus_addresses. A Modbus address in the range 2-255. This can be a hyphenated list like 3-10 or a list like 2,5,7,9

  • --port. This is an optional parameter used in an Ethernet gateway, and is the TCP port used for the gateway. Default is 502

  • --attempts. This is an optional parameter, and determines how many times to times to attempt to read an inverter value. Default is 1

  • --delay. This is the delay in seconds between inverter send and receive commands, AND if attempts > 1. Fractions like 0.3 can be used. Default is 0.05

  • --stop_on_any_command_fail. If this is specified, then any Modbus commands that fail will stop all further queries for all bus addresses and attempts.

  • --serial_lock. If this is set, the program can only be run one at a time (so as not to overload a Modbus device). If the device being queried is a serial device, this will automatically be set to "on". For IP addresses it is optional.

  • --sampling_rate. If this is defined, and the sampling rate is greater than 1, then all values listed above will be collected as an average. In other words; it will take a sample at the nominated frequency. After X samples defined by sampling_rate, a record will be written and sent to the cloud.